ANALISA JATUH TEGANGAN PADA JARINGAN TEGANGAN RENDAH Di PT.PLN (Persero) ULP Lembata

Elfira Dyah Ekawati, Fadly Lamataro, Titiek Suheta, M. Rizki Wicaksono, Yani  Ikhwanunnadzir

Abstract

We need good service quality in the electric power operating system, such as providing a good voltage value to customers and no voltage drop disturbance. This study determined the relationship between load balancing and voltage drop. It involved literature, observation, and interview methods. The analysis results at the LB.06 substation obtained the load value before load balancing on holidays in the morning and evening by 37.95% and 42.13%, while effective days gained 41.99% and 44.15%. The voltage drops after load balancing in holiday achieved R-phase 2.15%; 3.41%; S- phase 2.58%; 1.74%; and T-phase 3.56%; 5.98%. Meanwhile, effective days achieved R-phase 3.43%;4.27%, S-phase 1.73%;0.43%, and T-phase 2.60%;1.28%. In conclusion, load balancing was effective enough to reduce load and voltage drop values.

Keywords

voltage drop, load balancing, phase

Full Text:

PDF

References

I. Roza, “Analisis Tegangan Jatuh Lokasi Penempatan Trafo Distribusi 20 kV Untuk Penyaluran Energi,” Jesce, vol. 1, no. 2, 2018, [Daring]. Tersedia pada: http://ojs.uma.ac.id/index.php/jesce.

I. Hajar, N. Pasra, dan D. Rusmansyah, “Analisis Voltage Drop Pada Jaringan Tegangan Rendah Dengan Metode Pecah Beba Pada Gardu KH 007 Di PT PLN (Persero) UP3 Pamekasan,” Sutet, vol. 10, no. 2, hal. 99–111, 2020, doi: 10.33322/sutet.v10i2.1306.

N. Septiani, S. Thaha, dan N. Muchtar, “Analisis Drop Tegangan Pada Jaringan Tegangan Rendah PT . PLN ( Persero ) Unit Layanan Pelanggan ( ULP ) Panakkukang,” Semin. Nas. Tek. Elektro dan Inform., vol. 3, no. September, hal. 129–135, 2021.

H. L. Latupeirissa, H. Muskita, dan C. Leihitu, “Analisis Kerugian Tegangan Pada Jaringan Tegangan Rendah (Jtr) 380/220 Volt Gardu Distribusi Politeknik Negeri Ambon,” J. Simetrik, vol. 8, no. 1, hal. 46–51, 2018, doi: 10.31959/js.v8i1.79.

S. P. Nurullah dan A. Hariyanto, “Analisis Perbaikan Jatuh Tegangan Pada JTR Dengan Metode Pemerataan Beban Di Gardu KD26A PT. PLN (Persero) Area Pondok Kopi,” hal. 79, 2020.

R. Syahputra, “TRANSMISI DAN DISTRIBUSI TENAGA LISTRIK,” Long Range Plann., vol. 28, no. 4, hal. 131, 1995, doi: 10.1016/0024-6301(95)94318-s.

S. Suripto, “Buku Ajar Sistem Tenaga Listrik,” Univ. Muhammadiyah Yogyakarta, hal. 1–59, 2016.

O. Kati, A. Khafabin, dan Suparno, “Studi Evaluasi Distribusi Jaringan Tegangan Rendah (JTR) pada Gardu JPR 047 Penyulang Merak,” Elsains J. Elektro, vol. 3, no. 1, hal. 31–36, 2021, [Daring]. Tersedia pada: https://jurnal.untag-sby.ac.id/index.php/EL-SAINS/article/view/31-36#:~:text=Sistem distribusi Jaringan Tegangan Rendah,mutu tegangan dan tingkat keandalan.

S. Hidayat, S. Legino, dan N. F. Mulyanti, “Penyeimbangan beban pada jaringan tegangan rendah gardu distribusi CD 33 penyulang Sawah di PT PLN ( Persero ) Area Bintaro,” J. Ilm. sutet, vol. 8, no. 1, hal. 21–27, 2018, [Daring]. Tersedia pada: https://stt-pln.e-journal.id/sutet/article/view/712.

I. wayan Suartika Made, Arta Wijaya, “Memperbaiki Drop Tegangan Di Daerah Banjar Tulangnyuh Klungkung,” Jur. Tek. Elektro, Fak. Tek. Univ. Udayana, vol. 9, no. Universitas Udayana Kampus Bukit Jimbaran, Bali, hal. 7, 2010.

A. Azis dan H. A. Nurdin, “Analisa Jarak Lindung Lighting Arrester Terhadap Transformator Daya 20 Mva Gardu Induk Sungai Juaro Palembang,” Tek. J. Tek., vol. 7, no. 1, hal. 106, 2020, doi: 10.35449/teknika.v7i1.134.

Perusahaan Listrik Negara, “Standar Konstruksi Jaringan Tegangan Menengah Tenaga Listrik,” PT. PLN, hal. 3–4, 2010.

Amalia Yunia Rahmawati, “ANALISIS TEGANGAN JATUH (DROP VOLTAGE) PADA UNIT BOILER DI PPSDM MIGAS CEPU MENGGUNAKAN ETAP,” no. July, hal. 1–23, 2020.

H. Asy, “PERBAIKAN JATUH TEGANGAN DAN REKONFIGURASI BEBAN PADA PANEL UTAMA PRAMBANAN,” Seminar, vol. 2011, no. Semantik, hal. 1–5, 2011.

Refbacks

  • There are currently no refbacks.