Analisa Koordinasi Proteksi Over Current Relay pada Gardu Induk Bangil

Wahyu Hendra Prasetya, Misbahul Munir, Novian Patria Uman Putra, Nasyith Hananur Rohiem, Ilmiatul Masfufiah

Abstract

A reliable protection system is tasked with tracking and finding faults quickly so that it can quickly isolate the disturbed system so that it does not interfere with the system above it. The protection system can be said to be reliable if when the disturbance is in progress, the closest cb will immediately work and cut off the electricity so as not to interfere with other systems. Therefore, a coordination system is needed, namely the Overcurrent Relay on the Pandaan and Sukorejo feeder channel reclosers. The coordination of this protection system is intended so that, when one of the BUS is disturbed, this system will feel an imbalance that causes the continuity of power flow to be disrupted, so it is necessary to set overcurrent relays in order to obtain good settings and electrical equipment can be avoided from all kinds of damage. After calculating and correcting the Over Current Relay setting on the Pickup Current and Time Dial values, the new settings applied have worked according to their respective functions when a disturbance occurs. The T value used from the closest to the load is 0.3, then 0.5 seconds, and the far end with the load is 0.9, then 1.1 seconds

Keywords

Protection System; Over Current Relay (OCR); Recloser, setting; Pickup Current; Time Dial

Full Text:

PDF

References

Syahputra, A. (2018). “ ANALISIS SETTING PROTEKSI OCR DAN GFR DI PENYULANG SRL-01 SRONDOL MENGGUNAKAN SOFTWARE ETAP 12.6.0 ”

Dewangga, A. S. (2015). Studi Koordinasi Proteksi Rele Arus Lebih, Diferensial Dan Ground Fault Pada Pt. Linde Indonesia, Cilegon.

Naparin, M. R. (2018). ANALISIS KOORDINASI PROTEKSI OVERCURRENT RELAY PADA JARINGAN DISTRIBUSI 70 kV PT MAKMUR SEJAHTERA WISESA.

Gokhale, S. S., & Kale, V. S. (2014). Application of the firefly algorithm to optimal over-current relay coordination. 2014 International Conference on Optimization of Electrical and Electronic Equipment, OPTIM 2014, (2), 150–154. https://doi.org/10.1109/OPTIM.2014.6850887

Santoso, A. (2018). Koordinasi Proteksi Over Current Relay Di Penyulang Palimanan Pt.Pln Rayon Sumber Cirebon.

Rachmad Hidayat Mastian Noor. (2017). Analisis Koordinasi Over Current Relay Untuk Gangguan Phasa Dan Tanah Di Pt.Kpc (Kaltim Prima Coal). Fakultas Teknologi Industri Institut Teknologi Nasional Malang (Vol. 53).

Refbacks

  • There are currently no refbacks.